Thursday, April 4, 2013

Third-generation device significantly improves capture of circulating tumor cells

Third-generation device significantly improves capture of circulating tumor cells [ Back to EurekAlert! ] Public release date: 3-Apr-2013
[ | E-mail | Share Share ]

Contact: Katie Marquedant
kmarquedant@partners.org
617-726-0337
Massachusetts General Hospital

System rapidly produces purifed solution of tumor cells for pathological, molecular analysis

A new system for isolating rare circulating tumor cells (CTCs) living solid tumor cells found at low levels in the bloodstream shows significant improvement over previously developed devices and does not require prior identification of tumor-specific target molecules. Developed at the Massachusetts General Hospital (MGH) Center for Engineering in Medicine and the MGH Cancer Center, the device rapidly delivers a population of unlabeled tumor cells that can be analyzed with both standard clinical diagnostic cytopathology and advanced genetic and molecular technology. The MGH team's report has been published in Science Translational Medicine.

"This new technology allows us to follow how cancer cells change through the process of metastasis," says Mehmet Toner, PhD, director of the BioMicroElectroMechanical Systems Resource Center in the MGH Center for Engineering in Medicine, the paper's senior author. "Cancer loses many of its tissue characteristics during metastasis, a process we have not understood well. Now for the first time we have the ability to discover how cancer evolves through analysis of single metastatic cells, which is a big step in the war against cancer."

The new device called the CTC-iChip is the third microchip-based device for capturing CTCs developed at the MGH Center for Engineering in Medicine. The first two systems relied on prior knowledge of a tumor-specific surface marker in order to sort CTCs from whole blood and required significant adjustment for each different type of cancer. The systems also required four to five hours to process a single blood sample.

The only U.S. Food & Drug Administration-cleared, commercially available device for capturing and enumerating CTCs the CELLSEARCH system developed by Veridex, LLC relies on magnetic nanoparticles that bind to the same epithelial protein used in the MGH -developed microchip-based devices and cannot always find CTCs present at very low numbers. In January 2011 the MGH entered into a collaborative agreement with Veridex and its affiliate Janssen Research & Development, LLC, to establish a center of excellence in research on CTC technologies.

Combining elements of both approaches magnetic labeling of target cells and microfluidic sorting the CTC-iChip works by putting a blood sample through three stages. The first removes from the sample, on the basis of cell size, all blood components except for CTCs and white blood cells. The second step uses a microfluidic process developed at the MGH to align the cells in a single file, allowing for extremely precise and rapid sorting. In the third stage, magnetically labeled target cells either CTCs tagged via the epithelial marker or white blood cells tagged on known blood-cell antigens are sorted out. Tagging white blood cells instead of CTCs leaves behind a population of unlabeled and unaltered tumor cells and doesn't rely on the presence of the epithelial marker or other known tumor antigens on the cell surface.

The new system was able to process blood samples at the extremely rapid rate of 10 million cells per second, handling a tube of blood in less than an hour. Both the mode of sorting out tagged CTCs, called tumor-antigen-dependent, and the technique that depletes white blood cells, called tumor-antigen-independent, recovered more than 80 percent of tumor cells from different types of cancer that had been added to blood samples. Comparison of the antigen-dependent-mode CTC-iChip with existing commercial technology for processing blood samples from patients with prostate, breast, pancreatic, colorectal and lung cancer showed the CTC-iChip to be more sensitive at detecting low levels of CTCs.

In the antigen-independent mode, the CTC-iChip successfully identified CTCs from several types of cancers that had lost or never had the epithelial marker, including triple-negative breast cancer and melanoma. CTCs isolated through this mode were put through standard cytopathological analysis, which revealed structural similarities to the original tumor, and detailed molecular genotyping of CTCs from a single patient found significant differences in gene expression patterns among individual CTCs.

"We're only beginning to identify potential applications of the ability to analyze how tumors mutate as they spread, but this should help improve our understanding of the fundamental genetic principles of metastasis," says Toner, the Benedict Professor of Surgery at Harvard Medical School (HMS). "We hope to develop this technology to the point where it could be used for early diagnosis, which is the 'Holy Grail' that all of us working on CTC technology have been striving for."

Ravi Kapur, PhD, of the Center for Engineering in Medicine, leader of the innovation team within the MGH Circulating Tumor Cell Center, says, "The CTC-iChip provides a first-in-class device for high-efficiency, high-speed tumor cell sorting from a clinically relevant blood volume. The chip is designed for mass manufacturing, and simple automation for clinical translation." The team is working with collaborators at Veridex and Janssen to refine the system for commercial development.

Study co-author Daniel Haber, MD, PhD, director of the MGH Cancer Center and Isselbacher/Schwartz Professor of Oncology at HMS, adds, "The study of cancer metastasis has been limited by the inability to quickly and reliably isolate tumor cells in transit in the blood. This new approach is likely to be a game changer in the field."

###

Support for this work comes from Veridex, a subsidiary of Johnson & Johnson, a "dream team" award from Stand Up to Cancer, and grants from the National Institutes of Health and other funders. The MGH has applied for a patent on the CTC-iChip technology. Co-lead authors of the Science Translational Medicine report are Emre Ozkumur and Ajay Shah of the MGH Center for Engineering in Medicine, and additional co-authors include Shyamala Maheswaran, PhD, of the MGH Cancer Center.

Massachusetts General Hospital, founded in 1811, is the original and largest teaching hospital of Harvard Medical School. The MGH conducts the largest hospital-based research program in the United States, with an annual research budget of more than $775 million and major research centers in AIDS, cardiovascular research, cancer, computational and integrative biology, cutaneous biology, human genetics, medical imaging, neurodegenerative disorders, regenerative medicine, reproductive biology, systems biology, transplantation biology and photomedicine. In July 2012, MGH moved into the number one spot on the 2012-13 U.S. News & World Report list of "America's Best Hospitals."


[ Back to EurekAlert! ] [ | E-mail | Share Share ]

?


AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert! system.


Third-generation device significantly improves capture of circulating tumor cells [ Back to EurekAlert! ] Public release date: 3-Apr-2013
[ | E-mail | Share Share ]

Contact: Katie Marquedant
kmarquedant@partners.org
617-726-0337
Massachusetts General Hospital

System rapidly produces purifed solution of tumor cells for pathological, molecular analysis

A new system for isolating rare circulating tumor cells (CTCs) living solid tumor cells found at low levels in the bloodstream shows significant improvement over previously developed devices and does not require prior identification of tumor-specific target molecules. Developed at the Massachusetts General Hospital (MGH) Center for Engineering in Medicine and the MGH Cancer Center, the device rapidly delivers a population of unlabeled tumor cells that can be analyzed with both standard clinical diagnostic cytopathology and advanced genetic and molecular technology. The MGH team's report has been published in Science Translational Medicine.

"This new technology allows us to follow how cancer cells change through the process of metastasis," says Mehmet Toner, PhD, director of the BioMicroElectroMechanical Systems Resource Center in the MGH Center for Engineering in Medicine, the paper's senior author. "Cancer loses many of its tissue characteristics during metastasis, a process we have not understood well. Now for the first time we have the ability to discover how cancer evolves through analysis of single metastatic cells, which is a big step in the war against cancer."

The new device called the CTC-iChip is the third microchip-based device for capturing CTCs developed at the MGH Center for Engineering in Medicine. The first two systems relied on prior knowledge of a tumor-specific surface marker in order to sort CTCs from whole blood and required significant adjustment for each different type of cancer. The systems also required four to five hours to process a single blood sample.

The only U.S. Food & Drug Administration-cleared, commercially available device for capturing and enumerating CTCs the CELLSEARCH system developed by Veridex, LLC relies on magnetic nanoparticles that bind to the same epithelial protein used in the MGH -developed microchip-based devices and cannot always find CTCs present at very low numbers. In January 2011 the MGH entered into a collaborative agreement with Veridex and its affiliate Janssen Research & Development, LLC, to establish a center of excellence in research on CTC technologies.

Combining elements of both approaches magnetic labeling of target cells and microfluidic sorting the CTC-iChip works by putting a blood sample through three stages. The first removes from the sample, on the basis of cell size, all blood components except for CTCs and white blood cells. The second step uses a microfluidic process developed at the MGH to align the cells in a single file, allowing for extremely precise and rapid sorting. In the third stage, magnetically labeled target cells either CTCs tagged via the epithelial marker or white blood cells tagged on known blood-cell antigens are sorted out. Tagging white blood cells instead of CTCs leaves behind a population of unlabeled and unaltered tumor cells and doesn't rely on the presence of the epithelial marker or other known tumor antigens on the cell surface.

The new system was able to process blood samples at the extremely rapid rate of 10 million cells per second, handling a tube of blood in less than an hour. Both the mode of sorting out tagged CTCs, called tumor-antigen-dependent, and the technique that depletes white blood cells, called tumor-antigen-independent, recovered more than 80 percent of tumor cells from different types of cancer that had been added to blood samples. Comparison of the antigen-dependent-mode CTC-iChip with existing commercial technology for processing blood samples from patients with prostate, breast, pancreatic, colorectal and lung cancer showed the CTC-iChip to be more sensitive at detecting low levels of CTCs.

In the antigen-independent mode, the CTC-iChip successfully identified CTCs from several types of cancers that had lost or never had the epithelial marker, including triple-negative breast cancer and melanoma. CTCs isolated through this mode were put through standard cytopathological analysis, which revealed structural similarities to the original tumor, and detailed molecular genotyping of CTCs from a single patient found significant differences in gene expression patterns among individual CTCs.

"We're only beginning to identify potential applications of the ability to analyze how tumors mutate as they spread, but this should help improve our understanding of the fundamental genetic principles of metastasis," says Toner, the Benedict Professor of Surgery at Harvard Medical School (HMS). "We hope to develop this technology to the point where it could be used for early diagnosis, which is the 'Holy Grail' that all of us working on CTC technology have been striving for."

Ravi Kapur, PhD, of the Center for Engineering in Medicine, leader of the innovation team within the MGH Circulating Tumor Cell Center, says, "The CTC-iChip provides a first-in-class device for high-efficiency, high-speed tumor cell sorting from a clinically relevant blood volume. The chip is designed for mass manufacturing, and simple automation for clinical translation." The team is working with collaborators at Veridex and Janssen to refine the system for commercial development.

Study co-author Daniel Haber, MD, PhD, director of the MGH Cancer Center and Isselbacher/Schwartz Professor of Oncology at HMS, adds, "The study of cancer metastasis has been limited by the inability to quickly and reliably isolate tumor cells in transit in the blood. This new approach is likely to be a game changer in the field."

###

Support for this work comes from Veridex, a subsidiary of Johnson & Johnson, a "dream team" award from Stand Up to Cancer, and grants from the National Institutes of Health and other funders. The MGH has applied for a patent on the CTC-iChip technology. Co-lead authors of the Science Translational Medicine report are Emre Ozkumur and Ajay Shah of the MGH Center for Engineering in Medicine, and additional co-authors include Shyamala Maheswaran, PhD, of the MGH Cancer Center.

Massachusetts General Hospital, founded in 1811, is the original and largest teaching hospital of Harvard Medical School. The MGH conducts the largest hospital-based research program in the United States, with an annual research budget of more than $775 million and major research centers in AIDS, cardiovascular research, cancer, computational and integrative biology, cutaneous biology, human genetics, medical imaging, neurodegenerative disorders, regenerative medicine, reproductive biology, systems biology, transplantation biology and photomedicine. In July 2012, MGH moved into the number one spot on the 2012-13 U.S. News & World Report list of "America's Best Hospitals."


[ Back to EurekAlert! ] [ | E-mail | Share Share ]

?


AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert! system.


Source: http://www.eurekalert.org/pub_releases/2013-04/mgh-tds040113.php

gold rush gold rush windows 8 Emanuel Steward nyc.gov SAT Notre Dame Football Schedule

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.